NEBS Certification
Retest Form www.lorusso.com
|
Description of product modification: |
DC/DC Converter - Alternate Component |
|
Network Critical? |
Yes. Failure could impact Network. |
|
Safety Critical? |
Yes. Critical Component in NRTL Report. |
|
Requirement |
Impact |
Test? |
Comments |
||
|
|
Minor |
Major |
Critical |
|
|
|
|
|
|
|
|
|
GR-1089-CORE |
|
|
|
|
|
|
|
|
|
|
|
|
|
ESD |
|
|
X |
YES |
NRTL. |
|
EMI Radiated |
|
|
X |
YES |
NRTL. |
|
EMI Immunity |
|
|
X |
YES |
NRTL. |
|
Lightning/AC Fault |
X |
|
|
|
|
|
Steady-State Ind. |
X |
|
|
|
|
|
DC Poten. Diff. |
X |
|
|
|
|
|
Safety |
X |
|
|
|
|
|
Corrosion |
X |
|
|
|
|
|
Bonding/Grounding |
|
|
X |
YES |
NRTL. |
|
|
|
|
|
|
|
GR-63-CORE |
|
|
|
|
|
|
|
|
|
|
|
|
|
T/H/A |
|
|
X |
YES |
NRTL. |
|
Heat Dissipation |
|
|
X |
YES |
NRTL. |
|
Fire Resistance |
X |
|
|
|
|
|
Handling |
|
|
X |
YES |
NRTL. |
|
Seismic |
|
|
X |
YES |
NRTL. |
|
Airborne Contam. |
|
X |
|
|
Pin for Pin direct replacement part. Testing not necessary. |
|
Acoustic |
X |
|
|
|
|
|
Illumination |
X |
|
|
|
|
|
|
|
|
|
|
|
SBC |
|
|
|
|
|
|
|
|
|
|
|
|
|
Input Voltage Range |
|
|
X |
YES |
NRTL. |
|
Low Transient |
|
|
X |
YES |
NRTL. |
|
High Transient |
|
|
X |
YES |
NRTL. |
|
Noise Induction |
|
|
X |
YES |
NRTL. |
|
|
|
|
|
|
|
|
NRTL
(Safety) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Input Current |
|
|
X |
YES |
NRTL. |
|
Leakage Current |
|
|
X |
YES |
NRTL. |
|
Dielectric Withstand |
|
|
X |
YES |
NRTL. |
|
Temperature Rise |
|
|
X |
YES |
NRTL. |
|
Bonding/Grounding |
|
|
X |
YES |
NRTL. |
|
Outside Plant |
X |
|
|
|
|